Description
Items DescriptionPower : 20HP/15KW
Voltage: 230V/60Hz/3ph;
Output Pipe Diameter : NPT 3/4”;
Air Flow : 81cfm-71cfm
Max Working Pressure : 125 psi/8 bar
Spin-on Air Oil Separator
Weight: 805 lbs
Package Size: 43*35*49 (inch)
Application
Air Brushing,Blow Cleaning,Bolting/Wrenching,Brad Nailing/Stapling,Cutting,Drilling,Finish Nailing,Framing Nailing,Grinding,
HVLP Painting,Hobby Nailing,Hobby Painting,Inflation,Roof Nailing,Sanding,Spraying,Surface Prep
Garage & Industrial & Light Duty
Features a programmable control system
Reduces your air system footprint and allows for easy maintenance
Caution
Please read the operate manual carefully before start the compressor working
— Don’t dismantle any connector or equipment when machine is
running. Otherwise, the high-pressure gas and high temperature will
hurt you seriously.
— Please pay more attention to parts such as pump, oil tank and
pipelines, because they are high temperature when machine is running.
— Don’t try to change the working pressure rated . Because change
working pressure exceeding the rated range will cause machines to
overload and stop to work.
——
— Provide proper grounding connection for electric parts according
to electric security regulations. Use suitable wires matching the
working power, otherwise they will burnt out due to high temperature
or some other dangerous events occur.
— The compressed air for breathe use is prohibit.
Regular maintenance interval schedule
Every 50 hours or weekly
--- Check oil level.
--- Check intake filter, if necessary clean it.
--- Drain condensation water from oil tank.
Every 500 hours
--- Check and adjust belt tension if necessary (belt driven only)
Every 2000 hours
--- Replace lubricants (for mineral lubricants oil)
--- Replace oil filter.
--- Replace intake filter
Every 4000 hours
--- Replace lubricants (for synthetic lubricants oil)
--- Replace oil separator
--- Clean cooler for dirt
Attention
1、Replace filter element and lubricant after first 500 hours of operation.
2、Use incorrect lubricant oil and spare parts will cause compressor damage, only use original
manufacture oil and parts.
3、The service life of compressor depends on the environment conditions such as dust, vent
etc.